Description
Sienna Electroencephalograph
Advanced Digital EEG System for Clinical Neurodiagnostics
Sienna Electroencephalograph is a comprehensive, modular digital EEG system designed for routine clinical studies and a broad range of electroencephalography applications.
Available in 40, 80, 120 and 160 channel configurations, Sienna combines EEG acquisition, review, analysis, digital video and remote monitoring capabilities within a flexible platform. Its modular architecture allows healthcare facilities to configure the system according to their clinical and workflow requirements.
Designed for modern neurodiagnostic environments, Sienna provides clinicians with an integrated solution for recording, reviewing, analysing and managing EEG data.
Flexible Multichannel EEG Recording
Configure the EEG System Around Your Clinical Requirements
Sienna is available in multiple channel configurations, from 40 to 160 channels, providing flexibility for different clinical and diagnostic requirements.
The modular architecture allows the system to be configured and upgraded with different hardware and software options.
This makes Sienna suitable for healthcare environments looking for a scalable multichannel EEG system rather than a fixed, single-purpose EEG platform.
Channel configurations include:
- 40-channel EEG
- 80-channel EEG
- 120-channel EEG
- 160-channel EEG
Advanced EEG Acquisition and Review
Sienna provides integrated EEG recording and review software designed to support the clinical workflow from signal acquisition through analysis and reporting.
The acquisition and review screens can be configured independently, while simultaneous split-screen recording and review allows users to monitor ongoing acquisition while reviewing recorded information.
The system also supports event marking and archiving, allowing selected events to be stored and accessed for subsequent review.
Efficient EEG Workflow
Designed to Simplify Clinical Workflows
Sienna incorporates a Workflow Manager designed to integrate routine tasks and improve productivity.
Users can quickly access parameter settings and analysis functions through a user-definable onscreen control-key layout.
The annotation system provides quick access to marked events, while data can also be reviewed according to event or time markers.
This workflow-focused design helps reduce unnecessary steps during EEG recording and review.
Remote EEG Monitoring
Monitor and Review EEG Data Over a Network
Sienna supports remote monitoring, reviewing and archiving over LAN, allowing EEG information to be accessed across a connected clinical environment.
Network connectivity can help support multi-station EEG environments where data needs to be accessed or reviewed from different locations.
This makes Sienna suitable for healthcare facilities seeking a connected digital EEG monitoring system.
High-Definition Digital Video
Combine EEG Data With Video Monitoring
Sienna supports Full HD digital video, providing the ability to combine EEG recording with synchronized visual information.
The system supports multiple camera options, with software-controlled pan, tilt and zoom capabilities available within the Sienna platform.
Video EEG can provide additional context when reviewing clinical events and recorded EEG activity.
Advanced EEG Analysis
Sienna provides a broad selection of software applications for EEG analysis.
FFT Spectrum Analysis
Frequency-domain analysis can be used to examine EEG activity across different frequency ranges.
Compressed Spectral Array
Provides a compact visual representation of spectral information over time.
Compressed Density Array
Supports visual analysis of EEG frequency distribution and changes over time.
Amplitude Mapping
Provides graphical representation of EEG amplitude distribution.
Advanced Analysis
Additional analysis programs can be integrated according to the selected configuration.
BESA Compatibility
Sienna supports BESA compatibility for applicable analysis workflows.
EEG Mapping and Evoked Potentials
Sienna can be configured with optional quantitative EEG, spectral analysis, mapping and evoked potential capabilities.
These options allow the platform to extend beyond basic EEG recording and support more advanced neurophysiological assessment requirements.
ERP functionality is also available as part of the Sienna software ecosystem.
Optional Spike and Seizure Detection
Sienna supports optional automatic spike and seizure detection capabilities.
These features can assist clinicians by highlighting potentially relevant EEG events for further review rather than requiring every section of a long recording to be examined manually.
The detection functions can be particularly relevant in EEG workflows involving prolonged recordings and epilepsy-related investigations.
Complete Polysomnography Capability
The Sienna platform can also support polysomnography (PSG) applications through its available software and hardware options.
This broader capability can help healthcare facilities use the platform across EEG and sleep-related diagnostic workflows.
For facilities that require both EEG and sleep-study capabilities, the Sienna ecosystem provides a flexible approach to system configuration.
Modular Design for Long-Term Flexibility
Build the System You Need
A key characteristic of Sienna is its modular design philosophy.
The hardware and software platform can be configured according to individual clinical requirements, with options available for different recording, analysis, video and monitoring applications.
The Sienna family also includes different physical configurations, including:
- Trolley-mounted systems
- Roll-stand configurations
- Desktop systems
- Portable solutions
This allows the EEG system to be selected according to the available clinical environment and workflow.
Integrated EEG Data Management
Sienna uses a common operating-platform approach across its system family.
This supports consistent data handling and helps users work across multiple EEG stations without having to adapt to completely different software environments.
A consistent workflow can be particularly useful for hospitals and diagnostic centres operating more than one EEG workstation.
Applications of Sienna Electroencephalograph
Sienna is designed for a broad range of digital EEG applications.
Routine EEG
Supports standard clinical EEG recording and review.
Long-Term EEG
Suitable configurations can support prolonged EEG recording workflows.
Video EEG
Full HD digital video can be integrated with EEG acquisition.
Epilepsy Monitoring
Optional spike and seizure detection can support epilepsy-related EEG review.
EEG Mapping
Amplitude mapping and quantitative analysis options extend the system’s analysis capabilities.
Evoked Potentials
ERP and evoked-potential functionality can be incorporated into applicable configurations.
Polysomnography
The Sienna platform supports complete polysomnography capabilities.
Remote Monitoring
LAN connectivity enables remote monitoring, reviewing and archiving.
Key Benefits of Sienna
40–160 Channel Configurations
Choose a channel configuration according to the requirements of the clinical environment.
Modular Architecture
Hardware and software options provide flexibility for different EEG applications.
Digital Video
Full HD digital video and multiple camera options support video EEG workflows.
Remote Monitoring
LAN connectivity enables remote monitoring, review and archiving.
Advanced Analysis
FFT, spectral analysis, mapping, ERP and additional analysis options are available.
Seizure Detection
Optional automatic spike and seizure detection supports efficient EEG review.
Flexible Installation
Trolley, roll stand, desktop and portable configurations are available across the Sienna product family.